Home › Guides › Solar Safety

Solar Safety: what goes wrong, and what your quote should show

Solar is one of the safest ways to power a home, when it's installed properly. Fires involving Solar panels have more than doubled since 2022, and the evidence points at installation, not the technology. Sparky's short answer first, then the Engineer's working.

Sources checked 9 October 2026. Listed at the bottom of the page.

Question 1

Is Solar safe?

Sparky the Squirrel says
Yes, when it's put in properly. Most problems come from how it's installed, not from the panels themselves.
🔧 The Engineer's Desk

The numbers are going the wrong way. UK fire services attended 91 fires involving Solar panels in 2022, 131 in 2023, 155 in 2024 and 212 in 2025, up 133%. Over the same years the number of installations grew by 52%. So fires are rising more than twice as fast as installations.

There's no routine national count of Solar fires. Official figures appear only in occasional Home Office releases, and the detailed year-by-year picture came out because an insurer, QBE, asked the fire services directly under Freedom of Information. In 2025, 88 of those fires spread beyond the installation itself.

The UK's government-commissioned study by BRE (2017) looked at more than 50 Solar fires. Installer error was the most common cause: problem installations 36%, faulty products 12%, system design 5%, and the rest had no single clear cause.

Question 2

What actually goes wrong?

Sparky says
Mostly the plugs, switches and cables on the roof side, where the power from the panels flows. A loose or wrong plug can spark.
🔧 The Engineer's Desk

In the 2025 fire-service figures, the biggest single cause was DC cabling and connectors (49 fires), ahead of the panels themselves (36), Battery banks (23) and inverters (19). DC is the side between the panels and the inverter, and it's live whenever there's daylight.

The BRE study found the same pattern: DC isolators (the roof-side off switches) were linked to up to 18 incidents and DC connectors to 10. A common thread was electrical arcing, a spark across a gap where parts have worked loose or were never properly joined.

One thing I always ask about is connectors from different makers pushed together. They can look identical and still not be a true match. Stäubli, who make the original MC4 connector, say plainly that their connectors may not be mated with other makers' connectors, and that doing so loses their safety certification. MCS installers must fit equipment to the manufacturer's instructions.

Question 3

Where should a home Battery go?

Sparky says
Ideally outside the house, in a garage or a shed. Not on your way out of the house in an emergency.
🔧 The Engineer's Desk

BSI has published a specification on exactly this: PAS 63100:2024, on protecting homes against fire from Battery storage. It isn't a British Standard or a law in itself, but it's the nationally agreed specification. It says that, where practicable, Batteries should be installed outdoors. It rules out bedrooms, escape routes (landings, stairs, hallways), lofts and roof voids, and cellars with no outside access. A garage can be fine, with limits on how big the Battery is and protection from knocks.

If your quote just says "Battery, installed", ask exactly where it will go, and why there.

Question 4

What should my quote show?

Sparky says
Five simple questions. If the installer can't answer them, that tells you something.
🔧 The Engineer's Desk

Put these five questions to your installer before you sign:

1. Are you MCS certified, and will I get an MCS certificate? (The insurer behind the fire figures advises using MCS-accredited installers.)
2. Where will the DC isolators go, and what are they rated for?
3. Will every DC connector pair be the same make and model?
4. If there's a Battery: where exactly, and how does that fit the fire-safety guidance above?
5. Which certificates and test results will I get at handover?

Not sure about the answers? Send me the quote and I'll check it for free. Safety is the first thing I look at.

Green

MCS certified, certificate promised

The installer is MCS certified and the quote says you'll get the MCS certificate and test results at handover.

Amber

"Battery, installed"

No location given. Ask exactly where it will go, and why there, against the PAS 63100 guidance above.

Red

Mixed-make DC connectors

Connector pairs from different makers pushed together. Stäubli say theirs may not be mated with other makers'.

Got a Solar quote in front of you? Don't sign yet.

I've spent 40+ years as an Engineer on safety-critical systems. Send me your quote and I'll check the safety items, the price and the promises, as a person, not a computer. It's free.

Check my quote →

Sources

All checked 9 October 2026.
QBE European Operations, press release, 10 August 2026: "Solar panel fires increasing at more than double the rate of installations" (UK fire service FOI data; installations from UK Government Solar PV statistics) — qbeeurope.com
BRE reports for BEIS on Solar PV fires, as reported by Solar Power Portal, 20 July 2017 — solarpowerportal.co.uk
Home Office, official statistics: fires attended by fire and rescue services involving solar panels, England — gov.uk
BSI, PAS 63100:2024 Electrical installations – Protection against fire of battery energy storage systems for use in dwellings – Specification — bsigroup.com
Stäubli, statement on PV connector product liability (25 March 2021) — staubli.com
WorkSafe NT (Australia), electrical safety bulletin on mismatched d.c. connectors — worksafe.nt.gov.au

General information only. It isn't a Survey and doesn't replace your installer's design, MCS checks or an Electrical Inspection.